Back to search

EXLIM R162-CV170

This surge arrester provides protection for switchgear, transformers and other equipment in high voltage systems against atmospheric and switching overvoltages.

Especially suitable for applications where:

–  Requirements of lightning intensity, energy capability and pollution are moderate

 

The EXLIM R-C is an excellent choice when a porcelain housed surge arrester is required.

Contact sales
General data
Unit
Neutral ground arrester
No
Family name
EXLIM
Type designation
R162-CV170
Design
MO, Gapless
Manufacturer country
Hitachi Energy, Sweden
Maximum system voltage (Us)

kVrms

170
Arrester classification as per IEC 60099-4 Ed. 3.0

Class

Station; SL
Nominal discharge current

kApeak

10
Rated voltage (Ur)

kVrms

162
Maximum continuous voltage (Uc)

kVrms

108
Frequency

Hz

15-62
TOV capability (after thermal energy rating Wth)
1s

kVrms

177
10s

kVrms

166
Charge, energy and current withstand data
Repetetive charge transfer rating Qrs

C

1,2
Thermal energy rating Wth

kJ/kV (Ur)

5
Discharge current withstand strength
High current, 4/10 μs

kApeak

100
Low current, 2000 μs

Apeak

600
Single-impulse Single-impulse withstand rating (IEEE), Repetitive charge transfer test value (IEC) - sample tests on all manufactured block batches

C

1,5
Energy data as per previous IEC standard IEC 60099-4, Ed 2.2
Line discharge class

Class

2
Energy capability - thermal energy capability (as per IEC 60099-4 Ed 2.2, clause 8.5.5)

kJ/kV (Ur)

5
Guaranteed max. protective data
Maximum residual/discharge voltage with current wave 30/60 μs (slow-front/switching)
0.5 kA

kVpeak

334
1.0 kA

kVpeak

347
2.0 kA

kVpeak

364
Maximum residual/discharge voltage with current wave 8/20 μs (fast-front/lightning)
5.0 kA

kVpeak

397
10 kA

kVpeak

421
20 kA

kVpeak

471
Maximum residual/discharge voltage with current wave 1/(2-20) μs (FOW as per IEEE, steep front as per IEC) External inductive effects neglected
10 kA

kVpeak

454
Technical data for housing
Short-circuit capability
High current, 0.2 s

kArms

50
Low current

Arms

600
External insulation - Requirements as per IEC 60099-4
LIWL, 1.2/50 μs

kVpeak

547
50 Hz, wet (60 s)

kVrms

251
SIWL, wet (250/2500 μs)

kVpeak

418
External insulation - Sum of tested values on individual empty unit housing
LIWL, 1.2/50 μs

kVpeak

788
50 Hz, wet (60 s)

kVrms

442
SIWL, wet (250/2500 μs)

kVpeak

640
Creepage distance (nominal)
mm

mm

5302
mm/kV (Us)

mm/kV (Us)

31
Creepage distance class
Very Heavy (31 mm/kV (Us))
Specified long-term load (SLL)

Nm

3000
Specified short-term load (SSL)

Nm

7500
Insulator colour/material
Brown Porcelain
Dimensions
Mass (kg)
120
Amax (mm)
1969
B (mm)
600
C (mm)
-
D (mm)
300
Shipping data
Unit
1-pack
Volume

kg

0,7
Gross

kg

148
2-pack
Volume

m3

-
Gross

kg

-
3-pack
Volume

m3

1,4
Gross

kg

418
6-pack
Volume

m3

-
Gross

kg

-
Each crate contains a certain number of arrester units and accessories for assembly and erection. A packing list is attached externally on each crate. Each separate crate is numbered and the numbers of all crates and their contents are listed in the shipping specification. Hitachi Energy reserves the right to pack arresters in the most effective/economic combination. Alternate or non-standard crates may involve additional charges. The table above is to be seen as an approximation and specific data for deliveries may differ from the values given.